Analysis of Operational Regimes of a High Power Water Load

E. Eugene Eves, Vadim V. Yakovlev

Journal of Microwave Power and Electromagnetic Energy · 2002 · 18 citations · 8 references

Concepts

Abstract

AbstractReflections, electric field and dissipated power of a 915 MHz water load produced by The Ferrite Company, Inc. are computed by QuickWave-3Dfor water temperatures from 5 to 60C. A simple empirical model generalizing experimental data is used for calculating the dielectric constant of fresh tap water at 915 MHz and for different temperatures. The computer model is verified by measurement of reflection’s magnitude and phase. The loads power reflection and patterns of electric field and dissipated power are demonstrated to be nearly independent of water temperature. Microwave power is dissipated primarily within the conical part of internal water cavity, and possible shortening of its cylindrical part (by up to 70 mm) is suggested for water temperatures less than 60°C The computational strategy used for modeling is assessed to be beneficia1for analyzing and designing other systems for microwave heating.Key Words: Electric fielddissipated powermicrowave powermodelpermittivityreflectiontap watertemperaturetransmissionwater load Additional informationNotes on contributorsE. EvesEugene Eves is affiliated with The Ferrite Company, Inc., Hudson, NH. Vadim Yakovlev is with the Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA.V. YakovlevEugene Eves is affiliated with The Ferrite Company, Inc., Hudson, NH. Vadim Yakovlev is with the Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA.

References

8