Foot & Ankle International · 2018 · 36 citations · 23 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomaterialsOrthopaedic BiomaterialsOrthopedicsAnkle ArthroplastyAnkle BiomechanicsArthroplasty BiomechanicsImplant BiomechanicsImplant DesignProsthetic MaterialsAnkle Joint ArthroplastyCrosslinked Polyethylene WearHighly Cross-linked PolyethyleneHighly Crosslinked PolyethylenePolyethyleneTotal Joint ArthroplastyUltra-high-molecular-weight PolyethyleneWear Particles
BACKGROUND: The aim of this study was to compare the polyethylene wear rate, particle size, and particle shape of primary semiconstrained, fixed-bearing, bone-sparing total ankle arthroplasty using conventional ultrahigh-molecular-weight polyethylene (CPE) versus highly cross-linked polyethylene (HXLPE) by applying a level walking input using a joint simulator. METHODS: Two fixed-bearing total ankle replacement systems with different types of polyethylene liners were tested: (1) CPE sterilized in ethylene oxide, and (2) HXLPE sterilized with gas plasma after electron beam irradiation. Three implants for each design underwent wear testing using gravimetric analysis over 5 million simulated walking cycles. A fourth implant was used as a load soak control. Equivalent circle diameter (ECD) and equivalent shape ratio (ESR) were computed to determine particle size and particle shape, respectively. RESULTS: particles/cycle, respectively ( P < .001). The mean ECD of HXLPE particles (0.22 ± 0.11 μm) was significantly smaller than the mean ECD of CPE particles (0.32 ± 0.14 μm) ( P < .001). HXLPE particles were significantly more round than CPE particles ( P < .001). CONCLUSIONS: HXLPE liners had a significantly lower wear rate and produced significantly fewer and rounder particles than CPE liners. The results of this study suggest that HXLPE has more favorable wear characteristics for total ankle arthroplasty. CLINICAL RELEVANCE: Polyethylene wear particles have been linked to osteolysis after total ankle arthroplasty. There is no consensus on the importance of highly cross-linked polyethylene in total ankle arthroplasty with regard to implant wear. This is the first nonindustry study to compare the polyethylene wear rate, particle size, and particle shape of fixed-bearing total ankle arthroplasty conventional polyethylene versus highly cross-linked polyethylene. The lower wear rate and different particle size/morphology of highly cross-linked polyethylene could be beneficial in vivo to decrease osteolysis.
23
Ebru Oral, Steven D. Christensen, Arnaz S. Malhi et al. · The Journal of Arthroplasty · 2006 · 303 citations · Full text
Natural Sciences, Materials Engineering, Materials Science +17
J.B. Matthews, A A Besong, Tim R Green et al. · Journal of Biomedical Materials Research · 2000 · 212 citations
Yasuharu Nakashima, Doo‐Hoon Sun, Michael C. D. Trindade et al. · Journal of Bone and Joint Surgery · 1999 · 209 citations
Akio Kobayashi, M. A. R. Freeman, W. Bonfield et al. · Journal of Bone and Joint Surgery - British Volume · 1997 · 196 citations