Review of Scientific Instruments · 2018 · 20 citations · 6 references
Natural SciencesNuclear EngineeringPhysicsFusion EngineeringNuclear InstrumentationPlasma PhysicsFusion PlasmasHigh-temperature PlasmasMicrowave MeasurementsPlasma ConfinementPlasma DiagnosticsPlasma TurbulenceDoppler MeasurementsDoppler Shift MeasurementsDoppler Spectrum AnalysisElectron Density FluctuationsFusion DiagnosticsPlasma Rotation DiagnosticsPlasma Source DiagnosticsReflectometry Diagnostics
The Doppler backward scattering (DBS) reflectometer has become a well-established and versatile diagnostic technique for the measurement of density fluctuations and flows in magnetically confined fusion experiments. In this work, a novel multiple fixed-frequency array source with a multiplexer technique is developed and applied in the multi-channel DBS system. The details of the system design and laboratory tests are presented. Preliminary results of Doppler shift frequency spectra measured by the multi-channel DBS reflectometer systems are obtained. Characteristics of plasma rotation and turbulence before and after supersonic molecular beam injection are analyzed.
6
A novel, multichannel, comb-frequency Doppler backscatter system
W. A. Peebles, T. L. Rhodes, J.C. Hillesheim et al. · Review of Scientific Instruments · 2010 · 109 citations
Natural Sciences, Physics, Acoustics +16
The radial electric field and its associated shear in the ASDEX Upgrade tokamak
J. Schirmer, G. D. Conway, H. Zohm et al. · Nuclear Fusion · 2006 · 89 citations · Full text
Microwave reflectometry for fusion plasma diagnosis
G. D. Conway · Nuclear Fusion · 2006 · 33 citations · Full text