Phase-Shifterless Power Controlled Combining Based on 20-kW S-Band Magnetrons With an Asymmetric Injection
26
Citations
12
References
2018
Year
Electrical Engineering20-Kw S-band MagnetronsAsymmetric Injection MagnetronsAsymmetric InjectionReal-time Phase-shifterless Power
A real-time phase-shifterless power controlled combining based on 20-kW S-band continuous-wave magnetrons with an asymmetric injection was proposed in this letter. A high-power-capacity combiner was designed, and the behaviors of the asymmetric injection magnetrons were qualitatively characterized. The system showed a nearly 3-MHz injection-locked bandwidth and an output power control range over 3 dB at an injection ratio of 0.07. An excellent spur suppression ratio of -65.0 dBc at 500 kHz, an output amplitude stability of 0.02 dB (peak to peak) and a phase stability of ±0.9° (peak to peak) were also demonstrated. To the best of our knowledge, the power output of 34.0 kW with a total combining efficiency of 86.7% sets a new performance record for an S-band continuous wave magnetron power combining system, which is one of the best spur suppressions among all reported S-band injection locked magnetrons with an output power of over 15 kW.
| Year | Citations | |
|---|---|---|
1963 | 911 | |
1991 | 260 | |
1998 | 221 | |
2016 | 52 | |
2005 | 48 | |
2009 | 44 | |
2014 | 37 | |
2003 | 32 | |
2017 | 31 | |
1947 | 17 |