Publication | Open Access
Mechanical properties of “two generations” of teeth aligners: Change analysis during oral permanence
77
Citations
28
References
2018
Year
EngineeringMechanical EngineeringBiomedical EngineeringOrthopaedic SurgeryDental MorphologyBiomechanicsTeeth AlignersOrthodontic TreatmentPolymer ChemistrySmart TrackFourier TransformMechanical PropertiesAdhesive MaterialPolymer ScienceDental BiomechanicsVitro StudyOral PermanenceOrthodontic ResearchMedicine
Aim of this in vitro study was to analyze structural properties of two different polymeric orthodontic aligners, Exceed30 (EX30) and Smart Track (LD30), before and after use. Forty patterns of aligners were randomly selected: 20 LD30 and 20 EX30, worn intra-orally for 14±3 days, 22 h/day. From each aligner, 10 specimens were prepared from buccal surfaces of the incisor region by the cutting of samples 5×5 mm under a stereomicroscope. All samples were subjected to Fourier transform infrared spectroscopy, micro-Raman spectroscopy, X-ray diffraction, tensile and indentation strength test. LD30 appeared more homogeneous, with a crystalline fraction lower than EX30 and exhibited a higher elastic behavior and a lower tendency to warp after use than EX30. LD30 demonstrated better adaptability to the dental arch and greater consistency of application of orthodontic forces than produced with EX30. However, both materials showed structural modifications that resulted in increased sample hardness and hyper-plasticity.
| Year | Citations | |
|---|---|---|
Page 1
Page 1