PLoS ONE · 2018 · 13 citations · 22 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic Nuclear MedicineDiagnostic RadiologyColorectal CancerHepatobiliary ImagingLiver MetastasisResponse AssessmentTherapy Response AssessmentTumor ImagingColorectal Liver MetastasisLiver Metastases TreatmentLiver Metastasis ImagingLiver Metastasis Response AssessmentPositive Predictive ValueRadiation Response AssessmentTumor Response EvaluationTumor Response Prediction
The aim of this study was to evaluate a modified method of calculating the 99m Tc/ 90 Y tumorto-normal-liver uptake ratio (mT/N) based on SPECT/CT imaging, for use in predicting the overall response of colorectal liver tumors after radioembolization. A modified phantombased method of tumor-to-normal-liver ratio calculation was proposed and assessed. In contrast to the traditional method based on data gathered from the whole tumor, gamma counts are collected only from a 2D region of interest delineated in the SPECT/CT section with the longest tumor diameter (as specified in RECIST 1.1). The modified tumor-to-normal-liver ratio (mT/N1) and 90 Y predicted tumor absorbed dose (PAD) were obtained based on 99m Tc-MAA SPECT/CT, and similarly the modified tumor-to-normal-liver ratio (mT/N2) and 90 Y actual tumor absorbed dose (AAD) were calculated after 90 Y-SPECT/CT. Tumor response was assessed on follow-up CTs. Using the newly proposed method, a total of 103 liver colorectal metastases in 21 patients who underwent radioembolization (between June 2009 and October 2015) were evaluated in pre-treatment CT scans and 99m Tc-MAA-SPECT/CT scans and compared with post-treatment 90 Y-SPECT/CT scans and follow-up CT scans. The results showed that the mT/N1 ratio (p = 0.012), PAD (p < 0.001) and AAD (p < 0.001) were predictors of tumor response after radioembolization. The time to progression was significantly lengthened for tumors with mT/N1 higher than 1.7 or PAD higher than 70 Gy. The risk of progression for tumors with mT/N1 lower than 1.7 or PAD below 70 Gy was significantly higher. The mT/N2 ratio had no significant correlation with treatment results.
22
New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)
E. Eisenhauer, P. Therasse, Jan Bogaerts et al. · European Journal of Cancer · 2008 · 29.5K citations
Andrew S. Kennedy, Subir Nag, Riad Salem et al. · International Journal of Radiation Oncology*Biology*Physics · 2007 · 676 citations
Harpreet Wasan, Navesh Sharma, Volker Heinemann et al. · The Lancet Oncology · 2017 · 398 citations · Full text
Guy A. Van Hazel, Volker Heinemann, Navesh Sharma et al. · Journal of Clinical Oncology · 2016 · 348 citations