EngineeringPhysicsElectromagneticsMicroelectromechanical SystemsMicrofabricationBiofluid MechanicsMicrofluidic DevicesMicrofluidic SystemsMicrofluidic TransportMicrofluidicsPermanent MagnetsExperimental Study DesignFluid-particle CouplingMicrochannel DesignMicrochannel FlowMicrochannel HydrodynamicsMicrofluidic FlowMicrofluidic Particle ManipulationParticle Manipulation In Microfluidics
There has been increasing interest in the use of magnetic fluids to manipulate diamagnetic particles in microfluidic devices. Current methods for diamagnetic-particle focusing in magnetic fluids require either a pair of repulsive magnets or a diamagnetic sheath flow. We demonstrate herein a tunable, sheathless focusing of diamagnetic particles in a microchannel ferrofluid flow with a single set of overhead permanent magnets. Particles are focused into a single stream near the bottom wall of a straight rectangular microchannel, where a magnetic-field minimum is formed as a result of the magnetization of the ferrofluid. This focusing can be readily switched off and on by removing and replacing the permanent magnets. More importantly, the particle-focusing position can be tuned by shifting the magnets with respect to the microchannel. We perform a systematic experimental study of the parametric effects of the fluid-particle-channel system on diamagnetic-particle focusing in terms of a defined particle-focusing effectiveness.