Natural SciencesBiomedical EngineeringMaterials ScienceBiocompatibilityBiomaterialsSurface EngineeringImplant MaterialsImplantable BiomaterialsMetallic BiomaterialsSurface BiocompatibilitySurface Modification Of BiomaterialsSurface Modification Of ImplantsBiocompatibility ImprovementBiocompatible MaterialsBiomedical ApplicationsCell Viability AssaysSurface Alteration AssessmentSurface Modification Of Metallic ImplantsSurface Morphology AlterationSurface Properties
With increasing popularity of Electrical Discharge Machining (EDM) method upon part manufacturing precision with tailorable surface properties; the assessment of EDM process was therefore carried out concerning the surface alteration of medical grade Co-Cr alloy biomaterials. The samples surface were EDMed at different spark energy levels by varying current and On-time to investigate the surface characteristics, and it's biological responses. MTT assay and cytocompatibility test were conducted to examine the in-vitro biocompatibility confirming the higher competent cell viability and proficient RBC lysis for the surface treated with spark energy ranging from 960J–1500J. Here the experimental results revealed that application of low-current (5 A) and high On-time (200 µs) favors the synthesis of high-quality biocompatible substrates. Thus, surface modification of Co-Cr implants using EDM can be considered as a promising method for improving surface properties essential for biomedical applications.