EngineeringBiological EngineeringChemical EngineeringBioprocess EngineeringElectrochemistryFermentation ScienceAerobic FermentationElectrode PotentialsMicrobial FermentationOxygen TransferSubmerged FermentationWorking ElectrodesDissolved OxygenElectrode Potential EvolutionElectrode Potential MeasurementElectrode Potential RelationshipsOxygen Transfer In FermentationOxygen Transfer ReactionsRedox PotentialRedox Potential Changes
The platinum electrode potentials relative to the standard half cell depended on a pH value, dissolved oxygen concentration, equilibrium constant and oxidation reduction potentials of the liquid The overall potential change in submerged fermentation gave no independent information on these individual factors A thermostatic and pH-static apparatus excluded influences of temperatures and pH values on the electrode pontentials If the determination was completed for short time duration, potentials were governed by the dissolved oxygen tension. While the oxygen concentration was maintained at a same level, redox potential changes became a dominant. This measurement of redox potential, which gave the concentration of extremely low dissolved oxygen that could not be detected by the membrane-coated oxygen electrode, was practically useful for the control of aerobic fermentation