Using manual exchanges for an urgent-start peritoneal dialysis program

Mihran V. Naljayan, Farshid Yazdi, Efrain Reisin

Clinical Kidney Journal · 2018 · 13 citations · 5 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: Urgent-start peritoneal dialysis (USPD) was designed to avoid temporary hemodialysis initiation with a hemodialysis catheter. In these patients, PD is initiated within 2 weeks of catheter placement, but typically these prescriptions utilize automated peritoneal dialysis (APD) with a cycler. Manual exchanges have not been reported previously for USPD. We hypothesize that using multiple, low-volume manual exchanges, patients will have similar rates of peritonitis, exit-site infection (ESI), pericatheter leaks and discontinuation of PD in the first 3 months after initiation. METHODS: used 1000 mL dwell volumes during the first 7 days. Dwell times were 2-2.5 h for two to three exchanges per day. After 7 days of successful therapy, the dwell volumes were doubled. All patients were maintained on furosemide 160 mg twice daily. RESULTS: There were 20 patients enrolled in our USPD program. Our rates of peritonitis, ESI, pericatheter leak and discontinuation of PD were 5%, 0%, 5% and 5%, respectively. CONCLUSIONS: Manual exchange during USPD is a viable modality with similar results as APD. Using manual exchanges allows patients to be more ambulatory during the day when they are not dwelling, allows nurses to evaluate the amount of ultrafiltration and effluent characteristics and allows for training in manual exchanges as well.

References

5