PLoS ONE · 2018 · 20 citations · 24 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBreast ImagingBreast Lesion CharacterizationDiffusion ImagingMagnetic Resonance Contrast MechanismsMagnetic Resonance ImagingMedical ImagingApparent Diffusion Coefficient AnalysisDiffusion Kurtosis ImagingDiffusion Magnetic Resonance ImagingDiffusion Mri AcquisitionDiffusion Mri ModelingIntravoxel Incoherent Motion ImagingMagnetic Resonance Imaging Lesion EvaluationNormal Tissue Delineation
We prospectively examined the variability of non-Gaussian diffusion magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) measurements with different numbers of b-values and excitations in normal breast tissue and breast lesions. Thirteen volunteers and fourteen patients with breast lesions (seven malignant, eight benign; one patient had bilateral lesions) were recruited in this prospective study (approved by the Internal Review Board). Diffusion-weighted MRI was performed with 16 b-values (0-2500 s/mm2 with one number of excitations [NEX]) and five b-values (0-2500 s/mm2, 3 NEX), using a 3T breast MRI. Intravoxel incoherent motion (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm2 [ADC0] and kurtosis [K]) parameters were estimated from IVIM and Kurtosis models using 16 b-values, and synthetic apparent diffusion coefficient (sADC) values were obtained from two key b-values. The variabilities between and within subjects and between different diffusion acquisition methods were estimated. There were no statistical differences in ADC0, K, or sADC values between the different b-values or NEX. A good agreement of diffusion parameters was observed between 16 b-values (one NEX), five b-values (one NEX), and five b-values (three NEX) in normal breast tissue or breast lesions. Insufficient agreement was observed for IVIM parameters. There were no statistical differences in the non-Gaussian diffusion MRI estimated values obtained from a different number of b-values or excitations in normal breast tissue or breast lesions. These data suggest that a limited MRI protocol using a few b-values might be relevant in a clinical setting for the estimation of non-Gaussian diffusion MRI parameters in normal breast tissue and breast lesions.
24
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Denis Le Bihan, D Lallemand, Michèle Aubin et al. · Radiology · 1988 · 3.2K citations
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Anwar R. Padhani, Guoying Liu, Dow‐Mu Koh et al. · Neoplasia · 2009 · 2K citations · Full text
Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging
Robert J. McDonald, Jennifer S. McDonald, David F. Kallmes et al. · Radiology · 2015 · 1.3K citations
Medicine, Neuroscience, Radiology +14
Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo
Paul S. Tofts, David Lloyd, Chris A. Clark et al. · Magnetic Resonance in Medicine · 2000 · 265 citations · Full text
Medicine, Biophysics, Chemistry +16