Safety and Health at Work · 2017 · 11 citations · 15 references
EngineeringToxicologyEmergency ManagementFire ManagementFire Protection EngineeringFire DetectionFire ResponseFire Risk AssessmentFire SafetyFire Safety EngineeringEmergency Respiratory ProtectionFire Detection SystemsFire Gas MonitoringFire Protection SystemsFire Response StrategyFire Scene ExaminationRespiratory Protection ManagementResponder Protective Equipment
Hazardous work zones (i.e., hot , warm , and cold ) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the “warm zone” of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.
15
Robert D. Daniels, Travis L. Kubale, James H. Yiin et al. · Occupational and Environmental Medicine · 2013 · 333 citations · Full text
Health hazards of fire fighters: exposure assessment.
Paul W. Brandt‐Rauf, L F Fallon, T Tarantini et al. · Occupational and Environmental Medicine · 1988 · 148 citations · Full text