Clinical Otolaryngology · 2017 · 18 citations · 25 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyNeuroradiologyBrain ImagingImaging AssessmentMagnetic Resonance ImagingAudiovestibular FindingsAudiovestibular SymptomsCerebellopontine Angle LesionsDiagnostic Accuracy StudiesDiagnostic Testing AccuracyInterrater AgreementOutcome MeasuresPositive Predictive Value
OBJECTIVE: To evaluate diagnostic accuracy of high-resolution T2-weighted MRI (T2w) for detecting cerebellopontine angle (CPA) lesions compared to a combined protocol including gadolinium enhanced T1-weighted MRI (GdT1w). SETTING: Department of Radiology & Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands. PARTICIPANTS: A random sample of MRIs from 350 patients (700 CPAs) with asymmetrical audiovestibular complaints was used, acquired between 2013 and 2016. MAIN OUTCOME MEASURES: Sensitivity, specificity, positive and negative predictive values of T2w results compared to GdT1w and, in patients with any suggestion of CPA pathology, to the complete examination (T1w, GdT1w and T2w). Inter-rater agreement between an experienced neuroradiologist and a less experienced observer was calculated. RESULTS: Results of 678 CPAs in 340 patients were analysed. On T2w, the neuroradiologist identified all 27 lesions >2 mm in size out of a total of 30 CPA lesions (sensitivity: 90% [95% CI: 73.5%-97.9%]). Negative predictive value reached 99.5% (95% CI: 98.7-99.9). One missed lesion of 2 mm would have been detected in clinical practice, as this was one of 14 patients for which additional GdT1w would have been ordered based on T2w alone, increasing sensitivity to 93% (95% CI: 77.9%-99.2%) and negative predictive value to 99.7% (95% CI: 98.9%-100%). Inter-rater agreement for T2w was 98% (95% CI: 96.4-98.8). CONCLUSION: T2w has a very high diagnostic accuracy for the presence of CPA lesions in patients with asymmetrical audiovestibular complaints. However, in a screening protocol with T2w only, smallest vestibular schwannomas as well as rare differential diagnoses that probably only would be detected on GdT1w may remain unnoticed.
25
Statistics Notes: Diagnostic tests 1: sensitivity and specificity
Douglas G. Altman, J Martin Bland · BMJ · 1994 · 2.1K citations · Full text
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Elizabeth A. Sadowski, Lindsey Bennett, Micah R. Chan et al. · Radiology · 2007 · 1K citations
Medicine, Nephrology, Pathology +12
Nahathai Wongpakaran, Tinakon Wongpakaran, Danny Wedding et al. · BMC Medical Research Methodology · 2013 · 976 citations · Full text
Tomonori Kanda, Toshio Fukusato, Megumi Matsuda et al. · Radiology · 2015 · 867 citations
Medicine, Neurology, Neuroscience +17