European Journal of Nuclear Medicine and Molecular Imaging · 2017 · 169 citations · 28 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic Nuclear MedicineDiagnostic RadiologyComputed TomographyImage QualityImage Quality AssessmentImage Quality AssuranceMedical ImagingPositron Emission TomographyAccreditation AuditsAccreditation CriteriaClinical Image QualityDecay-corrected Standardized Uptake ValueFeedbackImaging Result Quality AssurancePet-computed TomographyRadiology Quality Standards
PURPOSE: From 2010 until July 2016, the EANM Research Ltd. (EARL) FDG-PET/CT accreditation program has collected over 2500 phantom datasets from approximately 200 systems and 150 imaging sites worldwide. The objective of this study is to report the findings and impact of the accreditation program on the participating PET/CT systems. METHODS: To obtain and maintain EARL accredited status, sites were required to complete and submit two phantom scans - calibration quality control (CalQC), using a uniform cylindrical phantom and image quality control (IQQC), using a NEMA NU2-2007 body phantom. Average volumetric SUV bias and SUV recovery coefficients (RC) were calculated and the data evaluated on the basis of quality control (QC) type, approval status, PET/CT system manufacturer and submission order. RESULTS: SUV bias in 5% (n = 96) of all CalQC submissions (n = 1816) exceeded 10%. After corrective actions following EARL feedback, sites achieved 100% compliance within EARL specifications. 30% (n = 1381) of SUVmean and 23% (n = 1095) of SUVmax sphere recoveries from IQQC submissions failed to meet EARL accreditation criteria while after accreditation, failure rate decreased to 12% (n = 360) and 9% (n = 254), respectively. Most systems demonstrated longitudinal SUV bias reproducibility within ±5%, while RC values remained stable and generally within ±10% for the four largest and ±20% for the two smallest spheres. CONCLUSIONS: Regardless of manufacturer or model, all investigated systems are able to comply with the EARL specifications. Within the EARL accreditation program, gross PET/CT calibration errors are successfully identified and longitudinal variability in PET/CT performances reduced. The program demonstrates that a harmonising accreditation procedure is feasible and achievable.
28
Recommendations on the Use of <sup>18</sup>F-FDG PET in Oncology
James Fletcher, Benjamin Djulbegović, Heloisa P. Soares et al. · Journal of Nuclear Medicine · 2008 · 1.1K citations · Full text
Medicine, Oncology, Cancer Screening +14
Procedure guideline for tumor imaging with F-18 FDG PET/CT
Dominique Delbeke, R. Edward Coleman, Milton J. Guiberteau et al. · 2006 · 628 citations