Improved TEM-cell for EMC tests of integrated circuits

Alexander V. Demakov, Maxim E. Komnatnov

2017 International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON) · 2017 · 13 citations · 2 references

Concepts

Abstract

In this paper, the construction of TEM-cell, which can be used for tests on radiated susceptibility and emissions of integrated circuits in the frequency range up to 5 GHz, is presented. Constructional features and advantages of proposed TEM-cell compared with classic constriction are described. Electrodynamic simulation of construction is completed and results of the analysis of frequency dependencies of the magnitude of reflection |511| and transmission |S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">21</sub> | coefficients are presented. Results of the simulation showed good matching with the 50 Ohm feeder (|S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sub> | ≤ -20 dB) and low losses (|S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">21</sub> | ≥ -3 dB) in considered frequency range. Evaluation of non-uniformity of electric field strength in test volume is represented. Its value doesn't exceed ±3 dB in the test volume of 30×30×5 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> .

References

2