Water Research · 2017 · 144 citations · 32 references
Natural SciencesEnvironmental EngineeringEnvironmental SciencesAnalytical ChemistryEnvironmental MonitoringSpectroscopyEnvironmental AnalysisFluorescence SpectroscopyMicrobial Pollution IndicatorsWater ChemistryWater PollutionWater QualityAbsorbance SpectroscopyDistribution System ContaminationDistribution System Water QualityDrinking Water Microbial QualityDrinking Water MonitoringDrinking Water Quality MonitoringOptical PropertiesWater Quality Indicators
Treated drinking water may become contaminated while travelling in the distribution system on the way to consumers. Elevated dissolved organic matter (DOM) at the tap relative to the water leaving the treatment plant is a potential indicator of contamination, and can be measured sensitively, inexpensively and potentially on-line via fluorescence and absorbance spectroscopy. Detecting elevated DOM requires potential contamination events to be distinguished from natural fluctuations in the system, but how much natural variation to expect in a stable distribution system is unknown. In this study, relationships between DOM optical properties, microbial indicator organisms and trace elements were investigated for households connected to a biologically-stable drinking water distribution system. Across the network, humic-like fluorescence intensities showed limited variation (RSD = 3.5-4.4%), with half of measured variation explained by interactions with copper. After accounting for quenching by copper, fluorescence provided a very stable background signal (RSD < 2.2%) against which a ∼2% infiltration of soil water would be detectable. Smaller infiltrations would be detectable in the case of contamination by sewage with a strong tryptophan-like fluorescence signal. These findings indicate that DOM fluorescence is a sensitive indicator of water quality changes in drinking water networks, as long as potential interferents are taken into account.
32
James L. Weishaar, George R. Aiken, Brian A. Bergamaschi et al. · Environmental Science & Technology · 2003 · 4.5K citations
PARAFAC. Tutorial and applications
Rasmus Bro · Chemometrics and Intelligent Laboratory Systems · 1997 · 2.8K citations
Orthogonal projections to latent structures (O‐PLS)
Johan Trygg, Svante Wold · Journal of Chemometrics · 2002 · 2.4K citations
Fluorescence spectroscopy and multi-way techniques. PARAFAC
Kathleen R. Murphy, Colin A. Stedmon, Daniel Graeber et al. · Analytical Methods · 2013 · 2K citations · Full text