Publication | Closed Access
Fiber-Optic Hybrid-Structured Fabry–Perot Interferometer Based On Large Lateral Offset Splicing for Simultaneous Measurement of Strain and Temperature
66
Citations
18
References
2017
Year
Optical MaterialsEngineeringOptical TestingInterferometryOptical MetrologyFiber OpticsCurrent HsfpiOptical PropertiesCalibrationSimultaneous MeasurementInstrumentationPhotonicsHigh SensitivityFiber Optic SensingThermal PhysicsAir CavityFiber OpticOptical SensorsOptical Sensor
We report a novel fiber-optic hybrid-structured Fabry-Perot interferometer (HSFPI) based on large lateral offset splicing for simultaneous measurement of strain and temperature with advantages of high sensitivity, low cost, and easy fabrication. The high-strain sensitivity of 28.95 pm/με and low-temperature sensitivity of 0.54 pm/°C are obtained for air cavity, and strain sensitivity of 28.95 pm/με is over five times compared to the current HSFPI (5.18 pm/με). In addition, strain and temperature sensitivities of silica cavity are, respectively, 1.59 pm/με and 12.71 pm/°C. Thus, due to the different sensitivities of air cavity and silica cavity to strain and temperature, this structure can be used to concurrently measure strain and temperature.