PubMed · 2017 · 30 citations · 38 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryImplant SurgeryJoint Replacement SurgeryOrthopedicsImplant DesignKnee ArthroplastyConstrained ProsthesesConstrained Revision ImplantsHost Bone IntegrationKnee Varus AlignmentPrimary Knee ArthroplastyRevision Knee Arthroplasty
Total knee arthroplasty is a successful operation that significantly improves patient's quality of life. However, studies demonstrated as only 82% to 89% of patients are satisfied with their surgery, being the other disappointed with regard to their expectations. Two to 5.7% of total knee arthroplasties (TKAs) require revision within 5 years. Both complex primary cases and revision TKA often necessitate for a higher degree of constrain than cruciate retaining or postero-stabilized implant design. In the 1970s varus-valgus constrained (VVC) or semi-constrained implants have been developed by Insall and associates from the PS design, which provide varus-valgus stability preserving a fair amount of host bone. VVC TKAs allows for a small amount of movement in the coronal, antero-posterior and axial planes. In this paper, the authors give an overview of the indications, outcomes and technique for varus-valgus constrained implants, both in the setting of primary and revision knee arthroplasty.
38
A comparison of four models of total knee-replacement prostheses
JN Insall, Ranawat Cs, Paolo Aglietti et al. · Journal of Bone and Joint Surgery · 1976 · 878 citations
Joanne M. Jordan, Charles G. Helmick, Jordan B. Renner et al. · The Journal of Rheumatology · 2009 · 742 citations · Full text