Publication | Open Access
Assessment of acquired mucociliary clearance defects using micro‐optical coherence tomography
32
Citations
31
References
2017
Year
EngineeringInflammatory Lung DiseaseLung InflammationBiomedical EngineeringChronic RhinosinusitisCellular PhysiologyTissue ImagingPulmonary PharmacologyMolecular ImagingRadiologyOphthalmologyMedical ImagingMcc DefectsBackground DehydrationMicro‐optical Coherence TomographyOptical ImagingBiomedical ImagingPulmonary PhysiologyLung MechanicsOptical Coherence TomographyMedicineTomography
Background Dehydration of airway surface liquid (ASL) disrupts normal mucociliary clearance (MCC) in sinonasal epithelium, which may lead to chronic rhinosinusitis (CRS). Abnormal chloride (Cl − ) transport is one such mechanism that contributes to this disorder and can be acquired secondary to environmental perturbations, such as hypoxia at the tissue surface. The objective of this study was to assess the technological feasibility of the novel micro‐optical coherence tomography (μOCT) imaging technique for investigating acquired MCC defects in cultured human sinonasal epithelial (HSNE) cells. Methods Primary HSNE cell cultures were subjected to a 1% oxygen environment for 12 hours to induce acquired cystic fibrosis transmembrane conductance regulator (CFTR) dysfunction. Ion transport characteristics were assessed with pharmacologic manipulation in Ussing chambers. ASL, periciliary fluid (PCL), and ciliary beat frequency (CBF) were evaluated using μOCT. Results Amiloride‐sensitive transport (ΔI SC ) was greater in cultures exposed to hypoxia (hypoxia: −13.2 ± 0.6 μA/cm 2 ; control: −6.5 ± 0.1 μA/cm 2 ; p < 0.01), whereas CFTR‐mediated anion transport was significantly diminished (hypoxia: 28.6 ± 0.3 μA/cm 2 ; control: 36.2 ± 1.6 μA/cm 2 ; p < 0.01), consistent with acquired CFTR dysfunction and sodium hyperabsorption. Hypoxia diminished all markers of airway surface function microanatomy as observed with μOCT, including ASL (hypoxia: 5.0 ± 0.4 μm; control: 9.0 ± 0.9 μm; p < 0.01) and PCL depth (hypoxia: 2.5 ± 0.1 μm; control: 4.8 ± 0.3 μm; p < 0.01), and CBF (hypoxia: 8.7 ± 0.3 Hz; control: 10.2 ± 0.3 Hz; p < 0.01). Conclusion Hypoxia‐induced defects in epithelial anion transport in HSNE led to predictable effects on markers of MCC measured with novel μOCT imaging. This imaging method represents a technological leap forward and is feasible for assessing acquired defects impacting the airway surface.
| Year | Citations | |
|---|---|---|
Page 1
Page 1