Water Resources and Industry · 2017 · 60 citations · 60 references
EngineeringEnvironmental EngineeringEnvironmental SciencesReaction EngineeringWastewater TreatmentWater TreatmentIndustrial Effluent TreatmentIndustrial Wastewater TreatmentNutrient RemovalWastewater BiotreatmentWastewater CharacterizationWastewater PollutionIndustrial Wastewater CharacterizationIndustrial Wastewater ManagementOrganic Pollutant RemovalOxidation ProcessesPollutant RemovalPollutant Removal Efficiency AnalysisRemoval EfficiencyRemoval Efficiency Optimization
Comparison of UV, H2O2, Fe2+, UV/H2O2, UV/Fe2+, Fe2+/H2O2 and UV/Fe2+/H2O2 processes for the removal of percentage color, COD and electrical energy per order from the effluent distillery industry. The results showed that, UV/Fe2+/H2O2 process yield higher percentage color and COD removal with low electrical energy per order than UV, UV/H2O2, UV/Fe2+ process. To obtain the UV/Fe2+/H2O2 process performance by operating various parameters on the percentage color and COD removal using response surface methodology. A Regression quadratic model describing the percentage color and COD removal efficiency of UV/Fe2+/H2O2 process were developed and validate by analysis of variance. Experimental results showed that, UV/Fe2+/H2O2 process can effectively reduced 96.50% of color and 84.40% of COD removal of the distillery industry wastewater under the optimum conditions such as Fe2+–1.50 mM, H2O2–200 mM, COD–1500 ppm and pH–3.2, respectively. Result concluded that, UV/Fe2+/H2O2 process can be used effectively for the treatment of real industrial effluent.
60