Journal of Physics Conference Series · 2017 · 20 citations · 12 references
MedicineRadiation OncologyRadiologyNuclear PhysicsRadiation DosimetryRadiation PhysicsExternal Beam RadiotherapyMonte Carlo DosimetryMonte Carlo Radiation TransportParticle TherapyPhantom DosimetryRadiation TherapyCarbon Ion TherapyConformalityFragmentationMonte Carlo Dose ModelingMonte Carlo Dose SimulationRadiation Field CharacterizationRelative Biological Effectiveness DistributionSecondary Particle Dose Contribution
Heavy-particle therapy such as carbon ion therapy is currently very popular because of its superior conformality in terms of dose distribution and higher Relative Biological Effectiveness (RBE). However, carbon ion beams produce a complex mixed radiation field, which needs to be fully characterised. In this study, the fragmentation of a 290 MeV/u primary carbon ion beam was studied using the Geant4 Monte Carlo Toolkit. When the primary carbon ion beam interacts with water, secondary light charged particles (H, He, Li, Be, B) and fast neutrons are produced, contributing to the dose, especially after the distal edge of the Bragg peak.
12
Geant4 developments and applications
John E. Allison, K. Amako, J. Apostolakis et al. · IEEE Transactions on Nuclear Science · 2006 · 6.9K citations · Full text
Nuclear Reactions at High Energies
Robert Serber · Physical Review · 1947 · 562 citations