EngineeringComputer EngineeringElectrical EngineeringAutomotive ElectronicsEnergy SystemsPower ElectronicsAc-dc ConvertersConverter TopologiesDc-dc ConversionDc-dc ConvertersPower ManagementResonant ConvertersIsolated Converter TopologiesIsolated ConvertersIsolated Dc-dc ConverterIsolated Power ConvertersIsolated Resonant ConversionIsolation TopologiesResonant Dc-dc ConverterResonant Power Converters
Growth of electricity consumption for data center increases rapidly as computation continues to move into the cloud computing. Energy management has become a key issue for the next generation of data center. 48V to 12V step-down isolated converters are often required in server, telecom and automotive applications. Using resonant topology such as LLC realizes ZVS turn-on for all switches over the entire load range using magnetizing current and can achieve high level of efficiency [1], [2]. In this paper the control system and application of an Isolated dc-dc resonant converter is proposed for a conversion from 48V to 12V. The controller IC has been implemented in 0.16um lithography together with a DPWM with 195ps resolution and 40Ms/s ADC 7 bits pipeline converter. Experimental results of a 45A, 12V provided to show the effectiveness of the discussed system.