Optics Express · 2017 · 27 citations · 16 references
Natural SciencesChemistryAnalytical ChemistryOpticsSpectroscopyEmission SpectroscopyLaser SpectroscopyOptical SpectroscopyPhosphorescence SpectroscopyTemperature MeasurementFluorescence Spectral ShiftLaser Doppler VelocimetryLuminescence LifetimeOptical ThermometryPhosphorescence Lifetime AnalysisPhosphorsTemperature Dependence Of FlowVelocity
phosphor particles as they cross the probe volume. Luminescence lifetimes evaluated in the time domain and frequency domain indicate that in these experiments, interferences from in-phase signals such as stray excitation laser light are negligible. The dependence of the phase-shift on flow temperature is characterised. In the temperature sensitive range above 700 K, precise gas temperature measurements can be obtained (8.6 K at 840 K) with this approach.
16
Light Converting Inorganic Phosphors for White Light-Emitting Diodes
Lei Chen, Chun Che Lin, Chiao-Wen Yeh et al. · Materials · 2010 · 545 citations · Full text