Neurosurgical FOCUS · 2017 · 121 citations · 17 references
EngineeringNeurological SurgerySurgeryMedical RoboticsNeural EngineeringSystems NeuroscienceImage RegistrationRobot-assisted SurgeryAccuracyComparison AccuracyPatient Registration SystemsPatient-to-image RegistrationRegistration Error AnalysisSurgical Target Localization
OBJECTIVE The purpose of this study was to compare the accuracy of Neurolocate frameless registration system and frame-based registration for robotic stereoelectroencephalography (SEEG). METHODS The authors performed a 40-trajectory phantom laboratory study and a 127-trajectory retrospective analysis of a surgical series. The laboratory study was aimed at testing the noninferiority of the Neurolocate system. The analysis of the surgical series compared Neurolocate-based SEEG implantations with a frame-based historical control group. RESULTS The mean localization errors (LE) ± standard deviations (SD) for Neurolocate-based and frame-based trajectories were 0.67 ± 0.29 mm and 0.76 ± 0.34 mm, respectively, in the phantom study (p = 0.35). The median entry point LE was 0.59 mm (interquartile range [IQR] 0.25-0.88 mm) for Neurolocate-registration-based trajectories and 0.78 mm (IQR 0.49-1.08 mm) for frame-registration-based trajectories (p = 0.00002) in the clinical study. The median target point LE was 1.49 mm (IQR 1.06-2.4 mm) for Neurolocate-registration-based trajectories and 1.77 mm (IQR 1.25-2.5 mm) for frame-registration-based trajectories in the clinical study. All the surgical procedures were successful and uneventful. CONCLUSIONS The results of the phantom study demonstrate the noninferiority of Neurolocate frameless registration. The results of the retrospective surgical series analysis suggest that Neurolocate-based procedures can be more accurate than the frame-based ones. The safety profile of Neurolocate-based registration should be similar to that of frame-based registration. The Neurolocate system is comfortable, noninvasive, easy to use, and potentially faster than other registration devices.
17
A Randomized, Controlled Trial of Surgery for Temporal-Lobe Epilepsy
Samuel Wiebe, Warren T. Blume, John P. Girvin et al. · New England Journal of Medicine · 2001 · 3.5K citations · Full text
Solomon L. Moshé, Emilio Perucca, Philippe Ryvlin et al. · The Lancet · 2014 · 899 citations
Francesco Cardinale, Massimo Cossu, Laura Castana et al. · Neurosurgery · 2012 · 523 citations
Prasanna Jayakar, Jean Gotman, A. Simon Harvey et al. · Epilepsia · 2016 · 284 citations · Full text