Optics Express · 2017 · 25 citations · 31 references
EngineeringBiomedical EngineeringBiomedical ImagingDiagnostic ImagingOpticsFourier OpticsImage ReconstructionImagingOptical ImagingExposure Time DependenceHigh-frequency PerformanceIntensity AnalysisKöhler TheoryLow-frequency NoisePhase ReconstructionPhase RetrievalSource Diversity
The transport of intensity equation (TIE) is a phase retrieval method that relies on measurements of the intensity of a paraxial field under propagation between two or more closely spaced planes. A limitation of TIE is its susceptibility to low frequency noise artifacts in the reconstructed phase. Under Köhler illumination, when both illumination power and exposure time are limited, the use of larger sources can improve low-frequency performance although it introduces blurring. Appropriately combining intensity measurements taken with a diversity of source sizes can improve both low- and high-frequency performance in phase reconstruction.
31
Phase retrieval algorithms: a comparison
James R. Fienup · Applied Optics · 1982 · 5.6K citations
Three-dimensional model of purple membrane obtained by electron microscopy
Richard A. Henderson, P.N.T. Unwin · Nature · 1975 · 2.3K citations
Quantitative Phase Imaging Using Hard X Rays
K. Nugent, Timur E. Gureyev, David Cookson et al. · Physical Review Letters · 1996 · 669 citations