Advances in Mechanical Engineering · 2017 · 31 citations · 26 references
EngineeringMechanical EngineeringFluid DynamicsHydraulic EngineeringVibrationCavitationHydraulic MachineryHydraulic Pumping SystemsHydraulic SystemsHydraulic TransientsVibration MeasurementCavitation BehaviorCavitation In Hydraulic MachineryCavitation In Hydraulic SystemsCavitation InstabilityCavitation TestingCavitation-induced VibrationFlow InstabilitiesPump Cavitation
Numerical calculations and experimental measurements were carried out in a closed hydraulic test rig to investigate the vibration characteristics and instabilities induced by the development of cavitation in a centrifugal pump. The internal flow characteristics in the impeller and vibration signals at four different positions of the pump system were analyzed during the cavitation process. The results revealed that the occurrence and development of cavitation could be effectively detected by the sudden increase in the intensity of vibration at the testing points. Corresponding relationships were formulated between the occurrence and the development of cavitation and the intensification of the vibration at the measuring locations. It was found out that the virtual incipient for cavitation was much smaller than the traditional “critical” point.
26
Numerical simulation of unsteady cavitation flow in a centrifugal pump at off-design conditions
Zhu Bao Shan, Cao Shu Liang, Wang Yu Chuan et al. · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · 2013 · 129 citations
Engineering, Civil Engineering, Computational Fluid Dynamics +14
Noise as an indicator of cavitation in a centrifugal pump
M. Chudina · Acoustical Physics · 2003 · 107 citations