Development of an x-ray eight-image Kirkpatrick–Baez diagnostic system for China’s laser fusion facility

Yaran Li, Baozhong Mu, Qing Xie, Yanan He, Zhiqiang Chen, Zhanshan Wang, Zhurong Cao, Jianjun Dong, Shenye Liu, Yongkun Ding

Applied Optics · 2017 · 14 citations · 23 references

Concepts

Abstract

This article presents the development of an x-ray eight-image Kirkpatrick-Baez diagnostic system to be used at China's Shenguang-III (SG-III) laser facility in aspects of the optical design, multilayers, and online/offline tests. Six pieces of concave spherical substrates are used for constituting a special optical structure. Dual-periodic tungsten/carbon (W/C) multilayers are used for high reflectivity and large angular bandwidth of ∼0.1°. The global spatial resolution is ∼5 μm in the ±100 μm range. The schemes of system installation, transport, collimation, and image acquisition at China's SG-III facility are also discussed.

References

23