Journal of neurosurgery · 2017 · 90 citations · 15 references
MedicineNeurosurgerySurgeryCerebrovascular NeurosurgeryCerebrovascular SurgeryVascular SurgeryAneurysm RepairAneurysm SurgeryCerebrovascular DiseaseIntracerebral HemorrhageSubarachnoid HemorrhageSubarachnoid Hemorrhage ManagementDiverter TechnologyPeriprocedural MortalityPostprocedural BleedingRuptured Aneurysm ManagementRuptured Aneurysm RepairRuptured Intracranial Aneurysm ManagementSubarachnoid Hemorrhage ComplicationsSubarachnoid Hemorrhage Intervention
OBJECTIVE In this single-center series, the authors retrospectively evaluated the effectiveness, safety, and midterm follow-up results of ruptured aneurysms treated by implantation of a flow diverter device (FDD). METHODS The records of 17 patients (12 females, 5 males, average World Federation of Neurosurgical Societies score = 2.9) who presented with subarachnoid hemorrhage (SAH) due to the rupture of an intracranial aneurysm treated with an FDD were retrospectively reviewed. Of 17 ruptured aneurysms, 8 were blood blister-like aneurysms and the remaining 9 were dissecting aneurysms. The mean delay between SAH and treatment was 4.2 days. Intraprocedural and periprocedural morbidity and mortality were recorded. Clinical and angiographic follow-up evaluations were conducted between 6 and 12 months after the procedure. RESULTS None of the ruptured aneurysms re-bled after endovascular treatment. The overall mortality rate was 12% (2/17), involving 2 patients who died after a few days because of complications of SAH. The overall morbidity rate was 12%: 1 patient experienced intraparenchymal bleeding during the repositioning of external ventricular drainage, and 1 patient with a posterior inferior cerebellar artery aneurysm developed paraplegia due to a spinal cord infarction after 2 weeks. The angiographic follow-up evaluations showed a complete occlusion of the aneurysm in 12 of 15 surviving patients; of the 3 remaining cases, 1 patient showed a remnant of the aneurysm, 1 patient was retreated due to an enlargement of the aneurysm, and 1 patient was lost at the angiographic follow-up. CONCLUSIONS FDDs can be used in patients with ruptured aneurysms, where conventional neurosurgical or endovascular treatments can be challenging.
15
CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE
Pedro Lylyk, Carlos Miranda, Rosana Ceratto et al. · Neurosurgery · 2009 · 803 citations
Medicine, Neurosurgery, Surgery +14
István Szikora, Zsolt Berentei, Zsolt Kulcsár et al. · American Journal of Neuroradiology · 2010 · 565 citations · Full text
Medicine, Neurosurgery, Surgery +12
A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular Aneurysms
David F. Kallmes, Yong Hong Ding, Daying Dai et al. · Stroke · 2007 · 452 citations · Full text
Medicine, Neurosurgery, Surgery +9
Blood blisterlike aneurysms of the internal carotid artery
Hiroaki Yokoyama, Akira Uchino · Journal of neurosurgery · 1998 · 237 citations
Medicine, Neurosurgery, Surgery +16