A prospective randomized trial comparing patent blue and methylene blue for the detection of the sentinel lymph node in breast cancer patients

Régis Resende Paulinelli, Ruffo Freitas‐Júnior, Rosemar Macedo de Souza Rahal, Luis Fernando de Pádua Oliveira, Maria Helena Tavares Vilela, Marise Amaral Rebouças Moreira, Katyane Larissa Alves, Marina Berquó Peleja, Tatiane Coelho Capel de Resende

Revista da Associação Médica Brasileira · 2017 · 23 citations · 25 references

DOIFull text

Open access

Concepts

Abstract

INTRODUCTION:: Methylene blue is more widely available and less expensive than patent blue, with an apparently lower risk of anaphylaxis. OBJECTIVE:: The two dyes were compared regarding detection of the sentinel lymph node (SLN). METHOD:: A prospective, randomized trial involved 142 patients with invasive breast carcinoma. Sixty-nine (49.3%) assigned to patent blue (group A) and 71 (50.70%) to methylene blue (group B). Thirty-five patients (25.0%) were clinical stage III or IV; 55 (38.7%) had axillary lymph nodes affected; and 69 (49.3%) underwent neoadjuvant chemotherapy. Two patients were excluded because the dye type was not recorded. RESULTS:: Patients and tumor characteristics were similar in both groups. SLNs were identified in 47 women (68.1%) in group A and 43 (60.6%) in group B (p=0.35). SLNs were affected in 22 cases (51.2%) in group A and 21 (48.8%) in group B (p=0.62). The SLN was the only node affected in 12 cases (54.5%) in group A and six (33.3%) in group B (p=0.18). The time and degree of difficulty involved in identifying the SLN were similar in both groups. There were no complications or allergies. CONCLUSION:: Methylene blue performed as well as patent blue in identifying the SLN in breast cancer patients.

References

25