Acta Cirúrgica Brasileira · 2017 · 15 citations · 19 references
MedicineSurgeryBiocompatibilityBiomaterialsTissue EngineeringMesh ComplicationsPolymeric BiomaterialsAdhesionsIntraperitoneal AdministrationPolypropylenePostoperative Adhesion Formation
PURPOSE: To compare the polypropylene mesh (Marlex®) to Vicryl®, Parietex composite® and Ultrapro® meshes to assess the occurrence of adhesions in the intraperitoneal implantation. METHODS: Sixty Wistar rats were allocated into three groups: PP+V, in which all the animals received a polypropylene and a Vicryl® mesh; PP+PC, with the implantation of polypropylene and Parietex composite® meshes and PP+UP, in which there was implantation of polypropylene and Ultrapro®. Macroscopic analysis was performed 28 days later to assess the percentage of mesh area affected by adhesion. RESULTS: in the PP+ V group, the Vicryl® mesh showed lower adhesion formation (p=0.013). In the PP+PC, there were no differences between polypropylene and Parietex composite® (p=0.765). In the PP+UP group, Ultrapro® and polypropylene meshes were equivalent (p=0.198) . CONCLUSION: All the four meshes led to adhesions, with the Vicryl® mesh showing the least potential for its formation.
19
Evaluation of new prosthetic meshes for ventral hernia repair
Jacobus W. A. Burger, Jens A. Halm, A. R. Wijsmuller et al. · Surgical Endoscopy · 2006 · 225 citations
Prevention of Adhesion to Prosthetic Mesh
Martijne van ’t Riet, Peggy J. de Vos van Steenwijk, F. Bonthuis et al. · Annals of Surgery · 2003 · 198 citations · Full text
Medicine, Surgery, Biocompatibility +16