A rapid and efficient DNA extraction protocol from fresh and frozen human blood samples

Pokhraj Guha, Avishek Das, Somit Dutta, Tapas K. Chaudhuri

Journal of Clinical Laboratory Analysis · 2017 · 64 citations · 22 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: Different methods available for extraction of human genomic DNA suffer from one or more drawbacks including low yield, compromised quality, cost, time consumption, use of toxic organic solvents, and many more. Herein, we aimed to develop a method to extract DNA from 500 μL of fresh or frozen human blood. METHODS: ) were estimated to check the quality and quantity of the extracted DNA sample. Qualitative assessment of the extracted DNA was checked by Polymerase Chain reaction and double digestion of the DNA sample. RESULTS: Our protocol resulted in average yield of 22±2.97 μg and 20.5±3.97 μg from 500 μL of fresh and frozen blood, respectively, which were comparable to many reference protocols and kits. CONCLUSION: Besides yielding bulk amount of DNA, our protocol is rapid, economical, and avoids toxic organic solvents such as Phenol. Due to unaffected quality, the DNA is suitable for downstream applications. The protocol may also be useful for pursuing basic molecular researches in laboratories having limited funds.

References

22