Journal of Cardiovascular Magnetic Resonance · 2016 · 96 citations · 27 references
MedicineCardiologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiac AssessmentCardiac ImagingCardiac Signal ProcessingCardiovascular ImagingImage RegistrationMedical ImagingCardiac Cine ImagingCardiac Strain ImagingElastic RegistrationImage CoregistrationNon-rigid RegistrationQuantitative Cardiac ImagingRigid Registration
Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising technique for quantification of myocardial strain from steady-state free precession (SSFP) cine images. We sought to determine the variability of CMR-FT using a non-rigid elastic registration algorithm recently available in a commercial software package (Segment, Medviso) in a real-life clinical setting. Firstly, we studied the variability in a healthy volunteer who underwent 10 CMR studies over five consecutive days. Secondly, 10 patients were selected from our CMR database yielding normal findings ( normal group ). Finally, we prospectively studied 10 patients with known or suspected myocardial pathology referred for further investigation to CMR ( patient group ). In the patient group a second study was performed respecting an interval of 30 min between studies. All studies were manually segmented at the end-diastolic phase by three observers. In all subjects left ventricular (LV) circumferential and radial strain were calculated in the short-axis direction (Ecc SAX and Err SAX, respectively) and longitudinal strain in the long-axis direction (Ell LAX ). The level of CMR experience of the observers was 2 weeks, 6 months and >20 years. Mean contouring time was 7 ± 1 min, mean FT calculation time 13 ± 2 min. Intra- and inter-observer variability was good to excellent with an coefficient of reproducibility (CR) ranging 1.6% to 11.5%, and 1.7% to 16.0%, respectively and an intraclass correlation coefficient (ICC) ranging 0.89 to 1.00 and 0.74 to 0.99, respectively. Variability considerably increased in the test-retest setting with a CR ranging 4.2% to 29.1% and an ICC ranging 0.66 to 0.95 in the patient group. Variability was not influenced by level of expertise of the observers. Neither did the presence of myocardial pathology at CMR negatively impact variability. However, compared to global myocardial strain, segmental myocardial strain variability increased with a factor 2–3, in particular for the basal and apical short-axis slices. CMR-FT using non-rigid, elastic registration is a reproducible approach for strain analysis in patients routinely scheduled for CMR, and is not influenced by the level of training. However, further improvement is needed to reliably depict small variations in segmental myocardial strain.
27
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Elias A. Zerhouni, Dave Parish, Walter J. Rogers et al. · Radiology · 1988 · 1.4K citations
Medicine, Cardiology, Radiology +15
MR imaging of motion with spatial modulation of magnetization.
Leon Axel, L Dougherty · Radiology · 1989 · 1.2K citations
The Case for Using the Repeatability Coefficient When Calculating Test–Retest Reliability
Sharmila Vaz, Torbjörn Falkmer, Anne Passmore et al. · PLoS ONE · 2013 · 474 citations · Full text