Evacuation response behaviour of occupants in a large theatre during a live performance

Edwin R. Galea, Steven Deere, Charlie Hopkin, Hui Xie

Fire and Materials · 2017 · 51 citations · 8 references

Concepts

TL;DR

The evacuation occurred at the end of a live performance in the Marlowe Theatre, Kent, UK, and further studies are needed to assess whether the findings generalise to other seated venues such as cinemas, music venues and sports arenas. The study aims to discuss response phase behaviours, present response time data, and propose a generalised methodology for distributing response time in theatre evacuation simulations. The authors propose a generalised methodology to assign response times to occupants based on seat location for use in evacuation simulation models. The study found that occupant response times follow a log‑normal distribution that increases with seat distance from exit aisles and rows, and that these trends should be incorporated into agent‑based evacuation models. © 2017 John Wiley & Sons, Ltd.

Abstract

Summary This paper presents the results of an unannounced theatre evacuation involving 1200 occupants. The evacuation took place towards the end of a live theatre performance in the Marlowe Theatre in Kent, UK. In particular, Response Phase behaviours are discussed, and response time data is presented. A significant finding of this work which is different to other reported work is that the occupant response time distribution, while following the typical log‐normal distribution is related to the geometrical positioning of the occupants relative to proximity to exit aisles and exits. Response time is found to increase relative to seat distance from the exit aisles and distance of the seat row to an exit. The identified trends in response time distribution will have a profound impact on the analysis of evacuation times and congestion levels determined using agent based evacuation models and so should be represented within these models. Based on these findings, a generalised methodology is proposed to distribute response time within a theatre for use in evacuation simulation applications. Further experimental analysis is required to determine whether these observations can be generalised and applied to other seated venues such as cinemas, music venues and sports arenas. Copyright © 2017 John Wiley & Sons, Ltd.

References

8