Optimization of ultrasonication period for better dispersion and stability of TiO2–water nanofluid

I.M. Mahbubul, Elif Begüm Elçioğlu, R. Saidur

Ultrasonics Sonochemistry · 2017 · 200 citations · 33 references

DOIFull text

Open access

Concepts

Abstract

• Optimum ultrasound duration for TiO 2 –water nanofluid is 150 min. • Initial particle size is more effective than sonication time on stability. • Comparison with literature and statistical analysis provide useful conclusions. Nanofluids are promising in many fields, including engineering and medicine. Stability deterioration may be a critical constraint for potential applications of nanofluids. Proper ultrasonication can improve the stability, and possibility of the safe use of nanofluids in different applications. In this study, stability properties of TiO 2 –H 2 O nanofluid for varying ultrasonication durations were tested. The nanofluids were prepared through two-step method; and electron microscopies, with particle size distribution and zeta potential analyses were conducted for the evaluation of their stability. Results showed the positive impact of ultrasonication on nanofluid dispersion properties up to some extent. Ultrasonication longer than 150 min resulted in re-agglomeration of nanoparticles. Therefore, ultrasonication for 150 min was the optimum period yielding highest stability. A regression analysis was also done in order to relate the average cluster size and ultrasonication time to zeta potential. It can be concluded that performing analytical imaging and colloidal property evaluation during and after the sample preparation leads to reliable insights.

References