Counter-Current Flow Limitation inside Vertical Pipes

Yasunori Yamamoto, Michio MURASE, Kosuke Hayashi, Shigeo Hosokawa, Akio Tomiyama

JAPANESE JOURNAL OF MULTIPHASE FLOW · 2016 · 11 citations · 10 references

DOIFull text

Open access

Concepts

Abstract

Characteristics of counter-current flow limitation (CCFL) inside vertical pipes with sharp-edged upper end (CCFL-P/SE) and with round-edged upper and lower ends (CCFL-P) were evaluated to clarify the dependence of the limiting locations. The CCFL is defined by the relationship between the gas and liquid volumetric fluxes (JG and JL) under a quasi-steady state after onset of flooding. CCFL correlations were constructed for CCFL-P/SE and CCFL-P based on the previous experimental data. The correlations were compared to the characteristics of CCFL at the vertical pipes of the sharp-edged upper end (CCFL-U) and the sharp-edged lower end (CCFL-L). CCFL-P has the highest liquid volumetric flux when CCFL occurs, and the lowest is CCFL-L. For the Wallis correlation, selection of the characteristic length of w = D(1-β)Lβ (where D and L respectively denote the diameter and the Laplace capillary length) is quite important. Our results have indicated that CCFL-P/SE and CCFL-P are also expressed by β ≈ 0.5, CCFL-U is expressed by β = 1, and CCFL-L is expressed by β = 0.