Journal of Applied Crystallography · 2017 · 42 citations · 23 references
Natural SciencesMaterials EngineeringMaterials ScienceInstrumentationMaterials CharacterizationMechanical Behavior Of MaterialsIn-situ Stress MeasurementStrain MeasurementX-ray Data AnalysisX-ray DetectionX-ray DetectorsAluminium AlloysCarbon Steel AlloysPrecisionStress MeasurementTensile StrainTensile StrengthTensile TestingX-ray Diagnostics
Portable X‑ray stress analyzers using area detectors and cosα/full‑ring fitting are increasingly popular for their fast, single‑exposure measurements, but their accuracy is questioned because they rely on a single reflection and short sample‑to‑detector distances. This article presents a comprehensive analysis of the uncertainty associated with a state‑of‑the‑art commercial portable X‑ray device. The authors quantified instrument precision with annealed ferrite reference powders and tested stress accuracy by in‑situ tensile loading on 1018 carbon steel and 6061 aluminium alloy bars. The study found that precision and accuracy depend on the instrument tilt angle, the chosen hkl reflection, and the instrument, sample, and data‑analysis methods, and it proposes measurement protocols to improve stress assessment accuracy.
The use of portable X-ray stress analyzers, which utilize an area detector along with the newly adopted `cosα' or full-ring fitting method, has recently attracted increasing interest. In laboratory conditions, these measurements are fast, convenient and precise because they employ a single-exposure technique that does not require sample rotation. In addition, the effects of grain size and orientation can be evaluated from the Debye ring recorded on the area detector prior to data analysis. The accuracy of the measured stress, however, has been questioned because in most cases just a single reflection is analyzed and the sample-to-detector distances are relatively short. This article presents a comprehensive analysis of the uncertainty associated with a state-of-the-art commercial portable X-ray device. Annealed ferrite reference powders were used to quantify the instrument precision, and the accuracy of the stress measurement was tested by in situ tensile loading on 1018 carbon steel and 6061 aluminium alloy bar samples. The results show that the precision and accuracy are sensitive to the instrument (or sample) tilt angle (ψ 0 ) as well as to the selected hkl reflection of the sample. The instrument, sample and data analysis methods all affect the overall uncertainty, and each contribution is described for this specific portable X-ray system. Finally, on the basis of the conclusions reached, desirable measurement/analysis protocols for accurate stress assessments are also presented.
23
Computed radiography utilizing scanning laser stimulated luminescence.
Mitumasa Sonoda, Masao Takano, Junji Miyahara et al. · Radiology · 1983 · 865 citations
Imaging plate illuminates many fields
Yoshiyuki Amemiya, Junji Miyahara · Nature · 1988 · 500 citations