2002 · 16 citations · 3 references
EngineeringComputer EngineeringMechanical EngineeringAir ConditioningHeat TransferThermal AnalysisBuilding Cooling SystemsCooling SystemsHeat ExchangersPassive CoolingThermal DesignThermal ManagementCooling System ArchitectureCooling System DesignHeat DissipationHeat Pipe CoolingHeat Pipe TechnologyHeat PipesHeat SinksHybrid Cooling
This paper describes various cooling solutions using heat pipes for cooling of notebook PCs including: (1) a heat pipe with heat spreader plate; (2) a hybrid system, i.e. a heat pipe with heat sink and fan; and (3) a hinged heat pipe system. For heat input of less than 12 W, the thermal resistances measured between the CPU surface and ambient are: >8/spl deg/C/W for system (1) and 4-6/spl deg/C/W for systems (2) and (3). This means that the hybrid system and the hinged heat pipe systems are the most suitable candidates for cooling of the current CPU, which may require heat dissipation of more than 8 W at ambient of 40/spl deg/C and CPU maximum temperature of 95/spl deg/C. Experimental results of these three systems are included and discussed in this paper.
3
95/03996 Heat pipe science and technology
Fuel and Energy Abstracts · 1995 · 1.5K citations
Thermal solutions to Pentium processors in TCP in notebooks and sub-notebooks
Hong Xie, M. Aghazadeh, W. Lui et al. · 2002 · 17 citations
Hinged heat pipes for cooling notebook PCs
Masahito Mochizuki, Yuji Saito, Kazuhiko Goto et al. · 2002 · 12 citations