Malaria Journal · 2017 · 83 citations · 22 references
Life SciencesBiologyEntomologyMass Spectrometric AnalysisParasitologyVector-borne Disease ControlMalariaMass SpectrometryMolecular Diagnosis Of ParasitesMosquito BiologyMosquito-borne DiseasesPathogen DetectionAnopheles MosquitoesMaldi-tof IdentificationMaldi-tof Mass SpectrometryMass Spectrometry-based DetectionMolecular Detection Of ParasitesMolecular Parasite DetectionMosquito ParasitismMosquito-borne Disease Diagnosis
BACKGROUND: Malaria is still a major public health issue worldwide, and one of the best approaches to fight the disease remains vector control. The current methods for mosquito identification include morphological methods that are generally time-consuming and require expertise, and molecular methods that require laboratory facilities with relatively expensive running costs. Matrix-Assisted Laser Desorption Ionization Time-Of-Flight Mass Spectrometry (MALDI-TOF MS) technology, routinely used for bacterial identification, has recently emerged in the field of entomology. The aim of the present study was to assess whether MALDI-TOF MS could successfully distinguish Anopheles stephensi mosquitoes according to their Plasmodium infection status. METHODS: C57BL/6 mice experimentally infected with Plasmodium berghei were exposed to An. stephensi bites. For the determination of An. stephensi infection status, mosquito cephalothoraxes were dissected and submitted to mass spectrometry analyses and DNA amplification for molecular analysis. Spectra were grouped according to mosquitoes' infection status and spectra quality was validated based on intensity and reproducibility within each group. The in-lab MALDI-TOF MS arthropod reference spectra database, upgraded with representative spectra from both groups (infected/non-infected), was subsequently queried blindly with cephalothorax spectra from specimens of both groups. RESULTS: The MALDI TOF MS profiles generated from protein extracts prepared from the cephalothorax of An. stephensi allowed distinction between infected and uninfected mosquitoes. Correct classification was obtained in blind test analysis for (79/80) 98.75% of all mosquitoes tested. Only one of 80 specimens, an infected mosquito, was misclassified in the blind test analysis. CONCLUSIONS: Matrix-Assisted Laser Desorption Ionization Time-Of-Flight Mass Spectrometry appears to be a promising, rapid and reliable tool for the epidemiological surveillance of Anopheles vectors, including their identification and their infection status.
22
Classification and Identification of Bacteria by Mass Spectrometry and Computational Analysis
Sascha Sauer, Anja Freiwald, Thomas Maier et al. · PLoS ONE · 2008 · 328 citations · Full text
Kennard Tan, Brandon Ellis, Renee T. Lee et al. · Journal of Clinical Microbiology · 2012 · 320 citations · Full text
George Dimopoulos, George K. Christophides, Stephan Meister et al. · Proceedings of the National Academy of Sciences · 2002 · 317 citations · Full text