ACS Applied Materials & Interfaces · 2016 · 48 citations · 30 references
EngineeringBiomedical EngineeringBiotechnologyBiosensorsElectroanalytical MethodsSensorsCell-based BiosensorsCell-surface ReceptorsElectrochemical BiosensorsElectrochemical SensorsNanomaterial-based BiosensorsNanosensorsBiosensor DevelopmentBiosensor StabilityCell Surface Receptor BiosensorsElectrochemical ImmunosensorsElectrochemical NanobiosensorsNanomaterial-based ImmunosensorsNanomaterial-modified ElectrodesNanoparticles
A mutiplex cytosensor based on a dual electrochemiluminescence (ECL) signal system was fabricated for in situ and simultaneous detection of the expression levels of multiple cell-surface receptors, mannose and epidermal growth factor receptor (EGFR), using luminol-capped gold nanoparticles (Au@luminol) and CdS quantum dots (CdS QDs) as potential-resolved ECL nanoprobes. Two spatially resolved areas on indium tin oxide (ITO) electrodes were modified with polyaniline (PANI) by electropolymerization, on which gold nanoparticles (AuNPs) were attached to strengthen conductivity and stability of the sensing interface. Human mucin1 protein (MUC1) aptamer was immobilized onto AuNPs for capturing MUC1-positive MCF-7 cells. Au@luminol and CdS QDs as ECL nanoprobes were covalently linked with concanavalin A (ConA) and epidermal growth factor (EGF) to label MCF-7 cells on the two areas of the cytosensor separately. Compared to conventional multiplex biosensor, we demonstrated a novel analysis platform for the simultaneous detection of multiple cell-surface receptors; it could provide two sensitive and potential-resolved ECL signals during one potential scanning and avoid cross-reactivity between the two nanoprobes. The quantification of MCF-7 cells on the two spatially resolved areas could be achieved over the linear range from 10 2 to 1.0 × 10 6 cells mL –1 with a detection limit of 20 cells mL –1 . This multiplex cytosensor was further applied for simultaneous quantitative evaluation of the expression levels of mannose and EGFR on MCF-7 cells, revealed that the average numbers of mannose and EGFR per captured MCF-7 cell were 1.2 × 10 6 and 0.86 × 10 5 with the relative standard deviation of 5.3% and 4.2%, respectively. The multiplex cytosensor was capable of evaluating multiple cell-surface receptors, which would be beneficial to developing a better diagnostic tool for diseases.
30
Mosaic Amplification of Multiple Receptor Tyrosine Kinase Genes in Glioblastoma
Matija Snuderl, Ladan Fazlollahi, Long P. Le et al. · Cancer Cell · 2011 · 709 citations · Full text
Shoujiang Xu, Yang Liu, Taihong Wang et al. · Analytical Chemistry · 2011 · 368 citations · Full text
High-Mannose Glycans are Elevated during Breast Cancer Progression
Maria Lorna A. De Leoz, Lawrence J.T. Young, Hyun Joo An et al. · Molecular & Cellular Proteomics · 2010 · 333 citations · Full text
Richard Elledge, Stephanie Green, R Pugh et al. · International Journal of Cancer · 2000 · 329 citations
Medicine, Endocrinology, Oncology +17