Proceedings of the Institution of Mechanical Engineers Part J Journal of Engineering Tribology · 2016 · 12 citations · 18 references
EngineeringElectrical EngineeringMechanical EngineeringActuatorsFluid DynamicsFluid MechanicsElectric ActuatorsVibration ControlBearing DampingNumerical Stability AnalysisSqueeze Film BearingsSqueeze-film Damping EffectsTransmissibilityTransmissibility Analysis
A numerical analysis is carried out in order to investigate the effect of the electric field on the performance characteristics of a three-pad hydrostatic squeeze film damper compensated with new electrorheological valve restrictors. The bearing design is composed of three identical hydrostatic bearing pads. Each hydrostatic bearing pad is fed with a negative electrorheological fluid through an electrorheological valve. The numerical analysis showed that the viscosity of a smart fluid inside to each electrorheological valve can be controlled by using an electric field in order to control the static and dynamic characteristics. The results presented in this study can be made more useful to control rotor vibrations and force transmissibility especially around the critical speeds.
18
Electrorheological suspensions
Hao Tian · Advances in Colloid and Interface Science · 2002 · 271 citations
On a negative electrorheological effect
C. Boissy, P. Atten, Jean‐Numa Foulc · Journal of Electrostatics · 1995 · 59 citations