Magnetic Resonance in Medicine · 2016 · 48 citations · 40 references
MedicineNeuroscienceRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingImage ReconstructionMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical Image AnalysisMedical ImagingCompressed Sensing Magnetic Resonance ImagingDirect EstimationDynamic Magnetic Resonance Imaging ReconstructionMagnetic ResonanceMagnetic Resonance PhysicsParameter MappingT1-weighted ImagingUndersampled Magnetic Resonance Imaging Reconstruction
PURPOSE: -weighted dynamic contrast enhanced (DCE) MRI methodology where tracer-kinetic (TK) parameter maps are directly estimated from undersampled (k,t)-space data. THEORY AND METHODS: The proposed reconstruction involves solving a nonlinear least squares optimization problem that includes explicit use of a full forward model to convert parameter maps to (k,t)-space, utilizing the Patlak TK model. The proposed scheme is compared against an indirect method that creates intermediate images by parallel imaging and compressed sensing before to TK modeling. Thirteen fully sampled brain tumor DCE-MRI scans with 5-second temporal resolution are retrospectively undersampled at rates R = 20, 40, 60, 80, and 100 for each dynamic frame. TK maps are quantitatively compared based on root mean-squared-error (rMSE) and Bland-Altman analysis. The approach is also applied to four prospectively R = 30 undersampled whole-brain DCE-MRI data sets. RESULTS: In the retrospective study, the proposed method performed statistically better than indirect method at R ≥ 80 for all 13 cases. This approach provided restoration of TK parameter values with less errors in tumor regions of interest, an improvement compared to a state-of-the-art indirect method. Applied prospectively, the proposed method provided whole-brain, high-resolution TK maps with good image quality. CONCLUSION: Model-based direct estimation of TK maps from k,t-space DCE-MRI data is feasible and is compatible up to 100-fold undersampling. Magn Reson Med 78:1566-1578, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
40
SENSE: Sensitivity encoding for fast MRI
Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al. · Magnetic Resonance in Medicine · 1999 · 6.1K citations
Blood-Brain Barrier Breakdown in the Aging Human Hippocampus
Axel Montagne, Samuel Barnes, Melanie D. Sweeney et al. · Neuron · 2015 · 2.1K citations · Full text
Magnetic resonance fingerprinting
Dan Ma, Vikas Gulani, Nicole Seiberlich et al. · Nature · 2013 · 1.6K citations · Full text