MedicineBiomedical EngineeringCardiologyDiagnostic ImagingInterventional CardiologyUltrasonographyDiagnostic UltrasonographyMedical ImagingMedical Imaging InstrumentationUltrasonicsUltrasound ImagingUltrasound InstrumentationCatheter-based Imaging DevicesEchocardiographic GuidanceInterventional FluoroscopyIntracardiac EchocardiographyIntracardiac Imaging GuidanceUltrasonic ImagingUltrasonic Transducer ArraysUltrasonic Transducer Design
Atrial fibrillation, the most common type of cardiac arrhythmia, now affects more than 2.2 million adults in the US alone. Currently, electrophysiological interventions are performed under fluoroscopy guidance, which besides its harmful ionizing radiation does not provide adequate soft-tissue resolution. Intracardiac echocardiography (ICE) provides realtime anatomical information that has proven valuable in reducing the fluoroscopy time and enhancing procedural success. We developed two types of forward-looking ICE catheters using capacitive micromachined ultrasonic transducer (CMUT) technology: MicroLinear (ML) and ring catheters. The ML catheter enables real-time forward-looking 2-D imaging using a 24-element 1-D CMUT phased-array that is designed for a center frequency of 10 MHz. The ring catheter uses a 64-element ring CMUT array that is also designed for a center frequency of 10 MHz. However, this ring-shaped 2-D array enables real-time forward-looking volumetric imaging. In addition, this catheter provides a continuous central lumen that enables convenient delivery of other devices such as RF ablation catheter, EP diagnostic catheter, biopsy devices, etc. Both catheters are equipped with custom front-end IC's that are integrated with the CMUT arrays at the tip of the catheters. The integration of the IC's with the CMUT arrays was accomplished using custom flexible PCB's. We also developed several image reconstruction schemes for the ring catheter on a PC-based imaging platform from VeraSonics. We performed a variety of bench-top characterizations to validate the functionality and performance of our fully integrated CMUT arrays. Using both catheters, we demonstrated in vivo images of the heart in a porcine animal model. We have successfully prototyped the first CMUT-based ICE catheters and proven the capabilities of the CMUT technology for implementing high-frequency miniature transducer arrays with integrated electronics.
8
Prevalence of Diagnosed Atrial Fibrillation in Adults
Alan S. Go, Elaine M. Hylek, Kathleen A. Phillips et al. · JAMA · 2001 · 6.2K citations
John W. Hirshfeld, Stephen Balter, Jeffrey Brinker et al. · Circulation · 2005 · 436 citations
John W. Hirshfeld, Stephen Balter, Jeffrey Brinker et al. · Journal of the American College of Cardiology · 2004 · 191 citations