2009 · 15 citations · 1 references
EngineeringElectrical EngineeringMicroelectronicsPower ElectronicsProcess ControlAccelerator PhysicsVoltage RegulationVoltage RegulatorsOutput Voltage RegulationVoltage
A two-part compensation scheme, Vernier Regulation, has been applied to offset the voltage droop (40% without correction) in a Marx-topology klystron modulator developed for the International Linear Collider (ILC). Coarse regulation, ±5%, is achieved by turning on additional Main Marx cells (Delayed Cells) sequentially as the droop reaches the cell voltage (11 kV). Further regulation to ±0.5% is achieved by adding a small Marx in series with the Main Marx. This Vernier Marx is composed of sixteen, 1.2 kV cells that are assembled as a seventeenth cell in the Main Marx. These Vernier Cells are turned on sequentially to generate a series of discrete corrections to the droop in the Main Marx cells with a step size ¿1% of the output voltage. As the required correction reaches 11 kV, all Vernier Cells are turned off synchronously with the turn on of a Delayed Cell. There are up to five Delayed Cells and six Vernier Marx cycles during each ILC Marx output pulse. The Vernier Marx has a local control system that will detect and respond to over-voltage and over-current errors. In this paper, a detailed description of the design, implementation and testing of the Vernier Marx is presented.
1
ILC Marx modulator development program status
C. Burkhart, T. Beukers, Mark A. Kemp et al. · 2009 · 22 citations