A practical device to determine the reflection coefficient of acoustic materials in-situ based on a Microflown and microphone sensor

Reinhilde Lanoye, Hans–Elias de Bree, Walter Lauriks, Gerrit Vermeir

2004 · 19 citations · 4 references

Concepts

Abstract

The reflection coefficient of acoustic absorbing materials is often measured in a standing wave tube. This method has some drawbacks. Here a novel technique, that is capable to determine the reflection coefficient in a fast way in-situ, real time, oblique and without the use of a standing wave tube, is presented. The method is based on the simultaneous measurement of normal acoustical particle velocity and sound pressure at the same position. These values are determined with the use of a Microflown (Titan sensor-element) and a sound pressure microphone. Theory is presented and supported by verifying measurements.

References

4