Journal of Analytical Toxicology · 2016 · 21 citations · 25 references
PharmacyPharmaceutical AnalysisPharmacologyChromatographic AnalysisForensic Pharmaceutical AnalysisPsychopharmacologyChromatographic Analysis Of PharmaceuticalsContaminant AnalysisExtraction TechniquesMetabolite ExtractionAnalytical Detection LimitsExtraction EfficiencyExtraction Of Organic CompoundsExtraction SolventsLimit Of Quantification DeterminationPharmaceutical ExtractionQuantification Limit AnalysisUnivariate Analysis
This paper reports, for the first time, the development of a modified Quick, Easy, Cheap Effective, Rugged and Safe (QuEChERS) combined with a dispersive SPE (d-SPE) based clean-up procedure as a new and powerful strategy for the simultaneous and efficient isolation of two different antidepressants, fluoxetine and clomipramine, and their active metabolites in human urine samples. A univariate experimental design with four independent variables such as sample volume, extraction solvent, buffered salts and clean-up step, was performed and used to investigate the effect of process variables on the extraction efficiency. Good linearity was achieved at the studied concentration range (0.1-5.0 g mL -1 ), with correlation coefficients (R 2 ) higher than 0.9961. Low detection limits, ranging between 0.060 and 0.092 g mL -1 were obtained for all analytes, whereas the lowest quantification limit was 0.1 g mL -1 , corresponding to the lowest concentration of the standard curve. The method also showed good results for accuracy, with values ranging from 91% to 105%. Intra-and inter-day precision, expressed as the relative standard deviation (RSD), were also satisfactory (<10%). Consistent recoveries of antidepressants ranging from 86% to 109% were observed when urine samples were fortified at three concentrations, namely 0.1, 2.5 and 5.0 g mL -1 . In order to evaluate the proposed method for clinical use, the QuEChERS/UHPLC-PDA method was applied to analysis of 12 urine samples from depressed patients. a RT: retention time. b max : maximum absorbance values obtained in PDA system detection. c TV: test value of Mandel's Fitting Test.
25
Michelangelo Anastassiades, Steven J. Lehotay, Darinka Štajnbaher et al. · Journal of AOAC International · 2003 · 5.5K citations
Steven J. Lehotay, Kateřina Maštovská, Alan R. Lightfield · Journal of AOAC International · 2005 · 620 citations
Choice Reviews Online · 2014 · 320 citations
Agriculture, Food Science, Nutrition +17
Charlotte Duverneuil, Geoffroy Lorin de la Grandmaison, Philippe de Mazancourt et al. · Therapeutic Drug Monitoring · 2003 · 149 citations
Chaomei Xiong, Jinlan Ruan, Yaling Cai et al. · Journal of Pharmaceutical and Biomedical Analysis · 2008 · 145 citations