The Journal of Strength and Conditioning Research · 2016 · 95 citations · 18 references
EducationKinesiologySports MedicineExercise PhysiologyExercise TestingHuman PerformanceMuscle StrengthMuscle Strength AssessmentMuscle Strength TestingMuscular StrengthMuscular Strength TestingPhysical FitnessExercise Test ReliabilityIntraclass CorrelationIsometric Strength TestingMuscular Strength AssessmentPeak Force MeasurementStrength Testing ReliabilityStrength Testing ValiditySubjects
De Witt, JK, English, KL, Crowell, JB, Kalogera, KL, Guilliams, ME, Nieschwitz, BE, Hanson, AM, and Ploutz-Snyder, LL. Isometric midthigh pull reliability and relationship to deadlift one repetition maximum. J Strength Cond Res 32(2): 528-533, 2018-The purpose of this investigation was to examine the reliability of the isometric midthigh pull (IMTP) and the relationship between IMTP peak force and deadlift 1 repetition maximum (1RM). Nine subjects (5 men and 4 women; 40.6 ± 8.0 years; 1.72 ± 0.10 m; 75.6 ± 13.4 kg) participated in this study. Isometric midthigh pull and deadlift 1RM were both performed during 2 testing sessions. For IMTP, peak force and peak rate of force development (RFD) were determined, in addition to RFD at 30 ms, 50 ms, 90 ms, 150 ms, 200 ms, and 250 ms after initiation of the pull. Intraclass correlation coefficients (ICCs) were calculated to evaluate the reliability of IMTP measures. Pearson product-moment correlations and linear regression were used to determine associations between IMTP and deadlift 1RM. Isometric midthigh pull peak force was reproducible both within (ICC = 0.98 and 0.97) and between sessions (ICC = 0.89) and significantly correlated with deadlift 1RM (r = 0.88, p ≤ 0.05), but intermediate force outputs and RFD were not. Lack of associations between RFD and deadlift 1RM indicate that the ability to create explosive force may be independent of the ability to create maximal force. The strong relationship between IMTP peak force and deadlift 1RM was present regardless of which IMTP repetition across the 2 sessions was examined. Peak force generated during IMTP is a reliable method to assess full body maximal strength. A single IMTP repetition, provided adequate familiarization and warm-up, correlates strongly with deadlift 1RM. Practitioners can use the IMTP test as a method to estimate maximal deadlift strength in a quick and potentially less provocative manner than traditional 1RM testing.
18
Bone mineral and lean tissue loss after long duration space flight.
A. LeBlanc, Victor Schneider, Linda Shackelford et al. · PubMed · 2000 · 472 citations
Medicine, Anatomy, Physiology +17
Scott M. Smith, Martina Heer, Linda Shackelford et al. · Journal of Bone and Mineral Research · 2012 · 342 citations · Full text