EngineeringMaterials EngineeringMaterials ScienceBiosensorsNanomaterialsSensorsBiosensors For Immune DetectionElectrochemical BiosensorsElectrochemical DetectionEnzyme-based BiosensorsMicrobial BiosensorsNanomaterial-based BiosensorsBiosensor CharacterizationChemical ModificationChemical Surface ModificationElectrochemical BiosensingElectrochemical ImmunosensorsImmunosensorsListeria DetectionNanomaterial-based Immunosensors
A sensitive and specific immunosensor was developed by immobilizing HRP-labeled antibody against Listeria monocytogenes onto the surface of the novel multiwalled carbon nanotube fibers. Firstly, the influence of immunoelectrode modification methods (chemical and physical method) on detection sensitivity and stability was studied. Next, immunosensor was developed, optimized, and applied for the detection of L. monocytogenes . The morphology was characterized by scanning electron microscopy (SEM), and electrochemical behaviors were by cyclic voltammetry. SEM image, relative response (%), and current data showed chemical modification for immunoelectrode was helpful to capture more target bacteria and obtain more stable current response, resulting in improving the detection sensitivity. The linear relationship between L. monocytogenes concentration and<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mrow><mml:mi>I</mml:mi></mml:mrow><mml:mrow><mml:mi mathvariant="normal">p</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:mrow></mml:msub></mml:math>was from 10 2 to 10 5 cfu/mL (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn fontstyle="italic">2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn fontstyle="italic">0.993</mml:mn></mml:math>), and LOD was<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><mml:mn fontstyle="italic">1.07</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mrow><mml:mn fontstyle="italic">10</mml:mn></mml:mrow><mml:mrow><mml:mn fontstyle="italic">2</mml:mn></mml:mrow></mml:msup></mml:math> cfu/mL. L. monocytogenes in mixed bacteria (1.51 × 10 3 cfu/mL) of milk sample (S/N > 14) were detected by developed immunosensor, showing good specificity. Good storage stability and reproducibility (RSD < 6.5%) also showed the potential application of immunosensor for the rapid detection of L. monocytogenes .
25
Hierarchically arranged helical fibre actuators driven by solvents and vapours
Peining Chen, Yifan Xu, Sisi He et al. · Nature Nanotechnology · 2015 · 372 citations