Scientific Reports · 2016 · 18 citations · 32 references
EngineeringBiotechnologyToxicologyBiosensorsNanotechnologySensorsBiological SensorsChemical SensorsMolecular SensorsNanomaterial-based BiosensorsNanosensorsSingle-molecule DetectionEmerging ContaminantsNanobiosensorsNanopore SensingNanopore-based DetectionTet-on TransactivatorTetracycline AntibioticsTetracycline-controlled TransactivatorsUltrasensitive Detection
Antibiotics as emerging environmental contaminants, are widely used in both human and veterinary medicines. A solid-state nanopore sensing method is reported in this article to detect Tetracycline, which is based on Tet-off and Tet-on systems. rtTA (reverse tetracycline-controlled trans-activator) and TRE (Tetracycline Responsive Element) could bind each other under the action of Tetracycline to form one complex. When the complex passes through nanopores with 8 ~ 9 nanometers in diameter, we could detect the concentrations of Tet from 2 ng/mL to 2000 ng/mL. According to the Logistic model, we could define three growth zones of Tetracycline for rtTA and TRE. The slow growth zone is 0-39.5 ng/mL. The rapid growth zone is 39.5-529.7 ng/mL. The saturated zone is > 529.7 ng/mL. Compared to the previous methods, the nanopore sensor could detect and quantify these different kinds of molecule at the single-molecule level.
32
Transcriptional Activation by Tetracyclines in Mammalian Cells
Manfred Gossen, Sabine Freundlieb, Gabriele Bender et al. · Science · 1995 · 2.5K citations
Ion-beam sculpting at nanometre length scales
Jiali Li, Derek Stein, Ciaran J. McMullan et al. · Nature · 2001 · 1.7K citations · Full text