CdZnTe Detectors Operating at X-ray Fluxes of 100 Million <inline-formula> <tex-math notation="LaTeX">$\mathrm {Photons}/(\mathrm {mm}^{2.}\mathrm {sec})$ </tex-math> </inline-formula>

Michael Prokesch, Stephen A. Soldner, Arunmozhi G. Sundaram, Handong Li, John Eger, Jaqueline L. Reiber, Carrie L. Shanor, Corey L. Wray, Aaron J. Emerick, Alan F. Peters,

IEEE Transactions on Nuclear Science · 2016 · 26 citations · 14 references

Concepts

Abstract

CdZnTe single crystals grown with the traveling heater method have been specifically engineered to support high-flux x-ray photon counting applications. Pixelated detector devices absorb hardened 120 kVp fluxes up to 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">8</sup> photons/(mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ·sec) without any sign of electric field polarization at room temperature (23-28) °C. It is shown that detector functionality can be verified using photon counting electronics even under conditions of strong pulse pile-up. A non-paralyzable counting model satisfactory describes the average output count rate of the detector-electronics system as a function of the absorbed flux. Good pixel-to-pixel count rate uniformity can be achieved.

References

14