Magnetic Resonance in Medicine · 2016 · 53 citations · 30 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiovascular ImagingFetal ImagingImage ReconstructionMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical ImagingCompressed SensingCompressed Sensing Magnetic Resonance ImagingCompressed Sensing ReconstructionImage BlurMagnetic ResonanceReconstruction Error AnalysisTime-resolved ImagingUndersampled Magnetic Resonance Imaging Reconstruction
Purpose To develop and validate a method for accelerated time-resolved imaging of the fetal heart using a combination of compressed sensing (CS) and metric optimized gating (MOG). Theory and Methods Joint optimization of CS and MOG reconstructions was used to suppress competing artifact from random undersampling and ungated cardiac motion. Retrospectively and prospectively undersampled adult and fetal data were used to validate the proposed reconstruction algorithm qualitatively based on visual assessment, and quantitatively based on reconstruction error, blur, and MOG timing error. Results Excellent agreement was observed between the fully sampled and retrospectively undersampled reconstructions, up to an undersampling factor of four. Visually, differences between ECG and MOG reconstructions of adult data were negligible. This was consistent with quantitative comparisons of reconstruction error (RMSEECG = 0.07–0.13; RMSEMOG = 0.08–0.13), and image blur (BECG = 1.03–1.20; BMOG = 1.03–1.20). The calculated MOG timing error (2–42 ms) was comparable to the acquired temporal resolution (∼60 ms). Quantitative evaluation of retrospectively undersampled (R = 2–8) fetal data (RMSEMOG = 0.06–0.12; BMOG = 1.04–1.27) was comparable to the adult volunteer results. Conclusion CS-MOG for dynamic imaging of the fetal heart was developed and validated. Using CS-MOG, images were obtained up to four times faster than conventional acquisitions. Magn Reson Med 77:2125–2135, 2017. © 2016 International Society for Magnetic Resonance in Medicine
30
David L. Donoho · IEEE Transactions on Information Theory · 2006 · 23.1K citations
SENSE: Sensitivity encoding for fast MRI
Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al. · Magnetic Resonance in Medicine · 1999 · 6.1K citations
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al. · Magnetic Resonance in Medicine · 2002 · 5.3K citations · Full text